Double Containment Couplings

We can't find products matching the selection.

Coupling


Part Number Type Size To Order
DC29-A005-A020 1/2X2 DBL CONT COUP SOC SCH40XSCH40 1/2X2 Contact Us
DC29-A005-G020 1/2X2 COUP DBL CONT SCH40XSCH40L 1/2X2 Contact Us
DC29-A007-A030 3/4X3 COUP DBL CONT SCH40XSCH40 3/4X3 Contact Us
DC29-A007-G030 3/4X3 COUP DBL CONT SCH40XSCH40L 3/4X3 Contact Us
DC29-A010-A030 1X3 COUP DBL CONT SCH40XSCH40 1X3 Contact Us
DC29-A010-G030 1X3 COUP DBL CONT SCH40XSCH40L 1X3 Contact Us
DC29-A015-A040 1-1/2X4 PVC COUP DBL CONT SCH40XSCH40 1-1/2X4 Contact Us
DC29-A015-G040 1-1/2X4 COUP DBL CONT SCH40XSCH40L 1-1/2X4 Contact Us
DC29-A020-A040 2X4 PVC COUP DBL CONT SCH40XSCH40 2X4 Contact Us
DC29-A020-G040 2X4 COUP DBL CONT SCH40XSCH40L 2X4 Contact Us
DC29-A030-A060 3X6 PVC COUP DBL CONT SCH40XSCH40 3X6 Contact Us
DC29-A030-G060 3X6 COUP DBL CONT SCH40XSCH40L 3X6 Contact Us
DC29-A040-A080 4X8 PVC COUP DBL CONT SCH40XSCH40 4X8 Contact Us
DC29-A040-G080 4X8 PVC COUP DBL CONT SCH40XSCH40L 4X8 Contact Us
DC29-A060-A100 6X10 DBL CONT COUP SOC SCH40XSCH40 6X10 Contact Us
DC29-A080-A120 8X12 COUP DBL CONT SCH40XSCH40 8X12 Contact Us
DC29-B005-A020 1/2X2 COUP DBL CONT SCH80XSCH40 1/2X2 Contact Us
DC29-B005-B020 1/2X2 DBL CONT COUP SCH80XSCH80 1/2X2 Contact Us
DC29-B005-G020 1/2X2 DBL CONT COUP SOC SCH80XSCH40L 1/2X2 Contact Us
DC29-B007-A030 3/4X3 DBL CONT COUP SOC SCH80XSCH40 3/4X3 Contact Us
DC29-B007-B030 3/4X3 DBL CONT COUP SCH80XSCH80 3/4X3 Contact Us
DC29-B007-G030 3/4X3 DBL CONT COUP SCH80XSCH40L 3/4X3 Contact Us
DC29-B010-A030 1X3 COUP DBL CONT SCH80PVCXSCH40PVC 1X3 Contact Us
DC29-B010-B030 1X3 COUP DBL CONT SCH80XSCH80 1X3 Contact Us
DC29-B010-G030 1X3 PVC COUP DBL CONT SCH80XSCH40L 1X3 Contact Us
DC29-B015-A040 1-1/2X4 DBL CONT COUP SCH80XSCH40 1-1/2X4 Contact Us
DC29-B015-B040 1-1/2X4 COUP DBL CONT SCH80XSCH80 1-1/2X4 Contact Us
DC29-B015-G040 1-1/2X4 DBL CONT COUP SOC SCH80XSCH40L 1-1/2X4 Contact Us
DC29-B020-A040 2X4 COUP DBL CONT SCH80XSCH40 2X4 Contact Us
DC29-B020-B040 2X4 PVC COUP DBL CONT SCH80XSCH80 2X4 Contact Us
DC29-B020-G040 2X4 PVC DBL CONT COUP SCH80XSCH40L 2X4 Contact Us
DC29-B030-A060 3X6 COUP DBL CONT SCH80XSCH40 3X6 Contact Us
DC29-B030-B060 3X6 PVC DBL CONT COUP SCH80XSCH80 3X6 Contact Us
DC29-B030-G060 3X6 DBL CONT COUP SCH80XSCH40L 3X6 Contact Us
DC29-B040-A080 4X8 COUP DBL CONT SCH80XSCH40 4X8 Contact Us
DC29-B040-B080 4X8 COUP DBL CONT SCH80XSCH80 4X8 Contact Us
DC29-B040-G080 4X8 PVC COUP DBL CONT SCH80XSCH40 CLR 4X8 Contact Us
DC29-B060-A100 6X10 COUP DBL CONT SCH80XSCH40 6X10 Contact Us
DC29-B060-B100 6X10 COUP DBL CONT SCH80XSCH80 6X10 Contact Us
DC29-B080-A120 8X12 COUP DBL CONT SCH80XSCH40 8X12 Contact Us
DC29-B080-B120 8X12 COUP DBL CONT SCH80XSCH80 8X12 Contact Us
DC29-C005-A020 1/2X2 COUP DBL CONT SCH80CPVCXSCH40 1/2X2 Contact Us
DC29-C005-B020 1/2X2 DBL CONT COUP SCH80CPVCXSCH80 1/2X2 Contact Us
DC29-C005-C020 1/2X2 COUP DBL CONT SCH80CPVCXSCH80CPVC 1/2X2 Contact Us
DC29-C005-G020 1/2X2 DBL CONT COUP SOC SCH80CPVCXSCH40L 1/2X2 Contact Us
DC29-C007-A030 3/4X3 COUP SCH80CPVCXSCH40PVC 3/4X3 Contact Us
DC29-C007-B030 3/4X3 DBL CONT COUP SOC S80CPVCXS80PVC 3/4X3 Contact Us
DC29-C007-C030 3/4X3 DBL CONT COUP SOC S80CPVCXS80CPVC 3/4X3 Contact Us
DC29-C007-G030 3/4X3 COUP DBL CONT SCH80CPVCXSCH40L 3/4X3 Contact Us
DC29-C010-A030 1X3 COUP DBL CONT SCH80CPVCXSCH40 1X3 Contact Us
DC29-C010-B030 1X3 COUP DBL CONT SCH80CPVCXSCH80 1X3 Contact Us
DC29-C010-C030 1X3 COUP DBL CONT SCH80CPVCXSCH80CPVC 1X3 Contact Us
DC29-C010-G030 1X3 COUP DBL CONT SCH80CPVCXSCH40L 1X3 Contact Us
DC29-C015-A040 1-1/2X4 COUP DBL CONT SCH80CPVCXSCH40 1-1/2X4 Contact Us
DC29-C015-B040 1-1/2X4 COUP DBL CONT SCH80CPVCXSCH80 1-1/2X4 Contact Us
DC29-C015-C040 1-1/2X4 COUP DBLCONT SCH80CPVCXSCH80CPVC 1-1/2X4 Contact Us
DC29-C015-G040 1-1/2X4 COUP DBL CONT SCH80CPVCXSCH40L 1-1/2X4 Contact Us
DC29-C020-A040 2X4 COUP DBL CONT SCH80CPVCXSCH40 2X4 Contact Us
DC29-C020-B040 2X4 DBL CONT COUP SCH80CPVCXSCH80PVC 2X4 Contact Us
DC29-C020-C040 2X4 PVC COUP DBLCONT SCH80CPVCXSCH80CPVC 2X4 Contact Us
DC29-C020-G040 2X4 COUP DBL CONT SCH80CPVCXSCH40L 2X4 Contact Us
DC29-C030-A060 3X6 COUP DBL CONT SCH80CPVCXSCH40 3X6 Contact Us
DC29-C030-B060 3X6 COUP DBL CONT SCH80CPVCXSCH80 3X6 Contact Us
DC29-C030-C060 3X6 COUP DBL CONT SCH80CPVCXSCH80CPVC 3X6 Contact Us
DC29-C030-G060 3X6 COUP DBL CONT SCH80CPVCXSCH40L 3X6 Contact Us
DC29-C040-A080 4X8 COUP DBL CONT SCH80CPVCXSCH40 4X8 Contact Us
DC29-C040-B080 4X8 COUP DBL CONT SCH80CPVCXSCH80PVC 4X8 Contact Us
DC29-C040-C080 4X8 COUP DBL CONT SCH80CPVCXSCH80CPVC 4X8 Contact Us
DC29-C040-G080 4X8 DBL CONT COUP SCH80CPVCXSCH40L 4X8 Contact Us
DC29-C060-A100 6X10 COUP DBL CONT SCH80CPVCXSCH40 6X10 Contact Us
DC29-C060-B100 6X10 COUP DBL CONT SCH80CPVCXSCH80 6X10 Contact Us
DC29-C060-C100 6X10 COUP DBL CONT SCH80CPVCXSCH80CPVC 6X10 Contact Us
DC29-C080-A120 8X12 COUP DBL CONT SCH80CPVCXSCH40 8X12 Contact Us
DC29-C080-B120 8X12 COUP DBL CONT SCH80CPVCXSCH80 8X12 Contact Us
DC29-C080-C120 8X12 DBLCONT COUPLER SCH80CPVCXSCH80CPVC 8X12 Contact Us

 

Isolation Coupling


Part Number Type Size To Order
DCDB-A005-A020 1/2X2 ISOLATION COUP DBLCONT SCH40XSCH40 1/2X2 Contact Us
DCDB-A005-G020 1/2X2 ISOLATION COUP DBLCON SCH40XSCH40L 1/2X2 Contact Us
DCDB-A007-A030 3/4X3 ISOLATION COUP DBLCONT SCH40XSCH40 3/4X3 Contact Us
DCDB-A007-G030 3/4X3 ISOLATON COUP DBLCONT SCH40XSCH40L 3/4X3 Contact Us
DCDB-A010-A030 1X3 ISOLATION COUP DBL CONT SCH40XSCH40 1X3 Contact Us
DCDB-A010-G030 1X3 ISOLATION COUP DBL CONT SCH40XSCH40L 1X3 Contact Us
DCDB-A015-A040 1-1/2X4 ISOLATION COUP DBL CONT S40XS40 1-1/2X4 Contact Us
DCDB-A015-G040 1-1/2X4 ISOLATION COUP DBL CONT S40XS40L 1-1/2X4 Contact Us
DCDB-A020-A040 2X4 ISOLATION COUP DBL CONT SCH40XSCH40 2X4 Contact Us
DCDB-A020-G040 2X4 ISOLATION COUP DBL CONT SCH40XSCH40L 2X4 Contact Us
DCDB-A030-A060 3X6 ISOLATION COUP DBL CONT SCH40XSCH40 3X6 Contact Us
DCDB-A030-G060 3X6 ISOLATION COUP DBL CONT SCH40XSCH40L 3X6 Contact Us
DCDB-A040-A080 4X8 ISOLATION COUP DBL CONT SCH40XSCH40 4X8 Contact Us
DCDB-A040-G080 4X8 ISOLATION COUP DBLCONT SCH040XSCH40L 4X8 Contact Us
DCDB-A060-A100 6X10 ISOLATION COUP DBL CONT SCH40XSCH40 6X10 Contact Us
DCDB-A080-A120 8X12 ISOLATION COUP DBL CONT SCH40XSCH40 8X12 Contact Us
DCDB-B005-A020 1/2X2 ISOLATION COUP DBLCONT SCH80XSCH40 1/2X2 Contact Us
DCDB-B005-B020 1/2X2 ISOLATION COUP DBLCONT SCH80XSCH80 1/2X2 Contact Us
DCDB-B005-G020 1/2X2 ISOLATION COUP DBLCON SCH80XSCH40L 1/2X2 Contact Us
DCDB-B007-A030 3/4X3 ISOLATION COUP DBLCONT SCH80XSCH40 3/4X3 Contact Us
DCDB-B007-B030 3/4X3 ISOLATION COUP DBLCONT SCH80XSCH80 3/4X3 Contact Us
DCDB-B010-A030 1X3 ISOLATION COUP DBL CONT SCH80XSCH40 1X3 Contact Us
DCDB-B010-B030 1X3 ISOLATION COUP DBL CONT SCH80XSCH80 1X3 Contact Us
DCDB-B010-G030 1X3 ISOLATION COUP DBL CONT SCH80XSCH40L 1X3 Contact Us
DCDB-B015-A040 1-1/2X4 ISOLATION COUP DBL CONT S80XS40 1-1/2X4 Contact Us
DCDB-B015-B040 1-1/2X4 ISOLATION COUP DBL CONT S80XS80 1-1/2X4 Contact Us
DCDB-B015-G040 1-1/2X4 ISOLATION COUP DBL CONT S80XS40L 1-1/2X4 Contact Us
DCDB-B020-A040 2X4 ISOLATION COUP DBL CONT SCH80XSCH40 2X4 Contact Us
DCDB-B020-B040 2X4 ISOLATION COUP DBL CONT SCH80XSCH80 2X4 Contact Us
DCDB-B020-G040 2X4 ISOLATION COUP DBL CONT SCH80XSCH40L 2X4 Contact Us
DCDB-B030-A060 3X6 ISOLATION COUP DBL CONT SCH80XSCH40 3X6 Contact Us
DCDB-B030-B060 3X6 ISOLATION COUP DBL CONT SCH80XSCH80 3X6 Contact Us
DCDB-B030-G060 3X6 ISOLATION COUP DBL CONT SCH80XSCH40L 3X6 Contact Us
DCDB-B040-A080 4X8 ISOLATION COUP DBL CONT SCH80XSCH40 4X8 Contact Us
DCDB-B040-B080 4X8 ISOLATION COUP DBL CONT SCH80XSCH80 4X8 Contact Us
DCDB-B040-G080 4X8 ISOLATION COUP DBL CONT SCH80XSCH40L 4X8 Contact Us
DCDB-B060-A100 6X10 ISOLATION COUP DBL CONT SCH80XSCH40 6X10 Contact Us
DCDB-B060-B100 6X10 ISOLATION COUP DBL CONT SCH80XSCH80 6X10 Contact Us
DCDB-B080-A120 8X12 ISOLATION COUP DBL CONT SCH80XSCH40 8X12 Contact Us
DCDB-B080-B120 8X12 ISOLATION COUP DBL CONT SCH80XSCH80 8X12 Contact Us
DCDB-C005-A020 1/2X2 ISOLATION COUP DBLCON SCH80CXSCH40 1/2X2 Contact Us
DCDB-C005-B020 1/2X2 ISOLATION COUP DBLCON SCH80CXSCH80 1/2X2 Contact Us
DCDB-C005-C020 1/2X2 ISOLATION COUP DBLCONT S80CXS80C 1/2X2 Contact Us
DCDB-C005-G020 1/2X2 ISOLATION COUP DBLCONT S80CXS40L 1/2X2 Contact Us
DCDB-C007-A030 3/4X3 ISOLATION COUP DBL CONT S80CXS40 3/4X3 Contact Us
DCDB-C007-B030 3/4X3 ISOLATION COUP DBL CONT S80CXS80 3/4X3 Contact Us
DCDB-C007-C030 3/4X3 ISOLATION COUP DBL CONT S80CXS80C 3/4X3 Contact Us
DCDB-C007-G030 3/4X3 ISOLATION COUP DBLCONT S80CXS40L 3/4X3 Contact Us
DCDB-C010-A030 1X3 ISOLATION COUP DBLCON SC80CXSCH40 1X3 Contact Us
DCDB-C010-B030 1X3 ISOLATION COUP DBLCON SCH80CXSCH80 1X3 Contact Us
DCDB-C010-C030 1X3 ISOLATION COUP DBL CON SCH80CXSCH80C 1X3 Contact Us
DCDB-C010-G030 1X3 ISOLATION COUP DBL CONT S80CXS40L 1X3 Contact Us
DCDB-C015-A040 1-1/2X4 ISOLATON COUP DBLCON S80CXS40 1-1/2X4 Contact Us
DCDB-C015-B040 1-1/2X4 ISOLATON COUP DBLCON S80CXS80 1-1/2X4 Contact Us
DCDB-C015-C040 1-1/2X4 ISOLATION COUP DBLCON S80CXS80C 1-1/2X4 Contact Us
DCDB-C015-G040 1-1/2X4 ISOLATION COUP DBLCON S80CXS40L 1-1/2X4 Contact Us
DCDB-C020-A040 2X4 ISOLATION COUP DBL CONT S80CXS40L 2X4 Contact Us
DCDB-C020-B040 2X4 ISOLATION COUP DBL CON S80CXSCH80 2X4 Contact Us
DCDB-C020-C040 2X4 ISOLATION COUP DBL CON SCH80CXSCH80C 2X4 Contact Us
DCDB-C020-G040 2X4 ISOLATION COUP DBL CON SCH80CXSCH40L 2X4 Contact Us
DCDB-C030-A060 3X6 ISOLATION COUP DBL CONT SCH80CXSCH40 3X6 Contact Us
DCDB-C030-B060 3X6 ISOLATION COUP DBL CONT SCH80CXSCH80 3X6 Contact Us
DCDB-C030-C060 3X6 ISOLATION COUP DBL CONT S80CXS80C 3X6 Contact Us
DCDB-C030-G060 3X6 ISOLATION COUP DBL CONT S80CXS40L 3X6 Contact Us
DCDB-C040-A080 4X8 ISOLATION COUP DBL CONT SCH80CXSCH40 4X8 Contact Us
DCDB-C040-B080 4X8 ISOLATION COUP DBL CONT SCH80CXSCH80 4X8 Contact Us
DCDB-C040-C080 4X8 ISOLATION COUP DBL CONT S80CXS80C 4X8 Contact Us
DCDB-C060-A100 6X10 ISOLATION COUP DBL CON SCH80CXSCH40 6X10 Contact Us
DCDB-C060-B100 6X10 ISOLATION COUP DBL CON SCH80CXSCH80 6X10 Contact Us
DCDB-C060-C100 6X10 ISOLATION COUP DBLCON SCH80CXSCH80C 6X10 Contact Us

Double containment couplings are advanced pipe connectors designed to join pipe lengths and provide a dual layer containment system for transporting corrosive, hazardous, or sensitive fluids. Available double containment (DC) coupling types include standard couplers and isolation couplers. DC couplings feature an inner and outer pipe, known as the carrier and containment pipes. Their design ensures that in the event of a leak or failure in the primary carrier pipe, the secondary containment pipe will capture the liquid material and prevent its release into the environment, avoiding loss and damages. Double containment couplers are used in dual pipe systems to connect individual pipe sections. They are used in industries that require or benefit from the safe transport of onsite fluids or materials. DC coupler fittings ensure that any leaks are contained within the secondary pipe, allowing the material to be recovered and providing sufficient time for repairs. They meet compliance with regulatory codes and safety guidelines for protecting personnel, equipment, and the environment.

Double Containment Coupling Sizes and Options

Double containment coupling sizes range from 1/2ʺ x 2ʺ up to 8ʺ x 12ʺ in carrier by containment diameters. Additional sizes are available on request. Double containment tees come in SCH 40 x SCH 40, SCH 80 x SCH 80, and combination SCH 40 x SCH 80 sizing standards. Fitting types include standard dual pipe couplings and specialized isolation couplings. Double containment isolation couplings feature an internal wall that functions as a barrier to isolate pipeline segments to greatly improve the ability of identifying leak locations. 

Double containment couplings come with separate internal carrier and external containment fittings in slip on socket joint configuration. Carrier fittings come with extenders to allow connections between carrier pipe components. DC couplings can be used with standard PVC or CPVC pipe, dual layer pipe, or clear piping. Double containment couplers are intended for solvent weld installation using primer and cement appropriate to the select fitting material and site conditions.

Technical Specifications

Our double containment couplings are made in the USA by Spears Manufacturing®, a trusted manufacturer of high quality products. They are manufactured from industrial strength PVC or CPVC thermoplastic material for heavy duty resilience and chemical compatibility. They are precision engineered to top technical and industry standards for exceptional performance and reliability. The fittings comply with ASTM, ISO, NSF, and UL standards for quality, consistency, and performance, and can be used to meet EPA secondary containment requirements. DC couplings are rated for SCH 40 or 80 operating pressures and working temperatures up to 140°F (PVC) or 200°F (CPVC). 

  • Material Profile: PVC Type I Class 12454 or CPVC Type IV Class 23447 
  • Material Options: PP or PVDF may also be available on request
  • Type: Pipe coupling or isolation coupling
  • Color: White, clear, or dark gray
  • ASTM Standards: D1784, D2466, D2467, F439, F2618, D3034, E84
  • Certifications: NSF 14, NSF 61, UL 94
  • Pressure: Full SCH 40 or SCH 80
  • Temperature: PVC: 140°F (60°C), CPVC: 200°F (93°C)
  • Sizing Standard: SCH 40 and SCH 80 
  • Size Options: 1/2ʺ x 2ʺ to 8ʺ x 12ʺ 
  • Connection Options: Slip on socket solvent weld

Features and Benefits

Double containment couplings offer a range of features and benefits ideal for meeting various industrial, manufacturing, and municipal needs. Their dual layer design provides superior leak prevention by containing releases within the outer pipe, offering workplace safety, regulatory compliance, and peace of mind. This design allows the integration of leak detection sensors for real time monitoring. They are constructed from high quality, heavy duty thermoplastic materials for durability, longevity, and resistance to corrosion, impact, and chemical attack. The fittings meet or exceed industry safety standards so facilities stay compliant with regulations and avoid fines and concerns of environmental damage. By reducing the risk of leak related incidents, double containment couplings offer a cost effective solution for dual pipe systems used to manage hazardous fluids.

  • Enhanced Safety: Dual containment design provides a secondary barrier against leaks to protect both personnel and the environment.
  • Chemical Resistance: PVC and CPVC materials for compatibility with a wide range of corrosive chemicals.
  • Durability: Engineered for long term performance with high impact and stress resistance.
  • Leak Detection: Compatible with various leak detection systems for proactive maintenance and preventative safety.
  • Ease of Installation: Slip on sockets and prefabricated components reduce installation time and labor costs.
  • Lightweight: Low weight synthetic makes for easy transport and installation.
  • Compliance: Built to meet regulatory codes for containment and release prevention for applications handling hazardous materials.

Applications and Uses

Double containment couplings are essential in the completion and compliance of dual pipe systems. They are used in various industrial, manufacturing, commercial, and municipal applications for the safe management of hazardous, corrosive, sensitive, or valuable fluids. In chemical processing plants, they safely transport aggressive chemicals, preventing leaks and contamination that could jeopardize safety and workflow. In the pharmaceutical industry, DC fittings handle sensitive and hazardous substances with precision while ensuring safe and uncontaminated transport. Wastewater treatment facilities benefit from their ability to manage abrasive and corrosive waste streams while protecting infrastructure and onsite operations. 

Ensure the highest safety, reliability, and compliance with our industry leading solutions. Don't compromise on safety — choose double containment couplings for unparalleled protection and performance of critical pipelines that handle hazardous or corrosive chemicals and application materials. Explore our extensive product range and discover the difference PVC Pipe Supplies can offer with our professional products and lowest price guarantee. To learn how our double containment couplings can protect your operations, meet regulatory compliance, and provide peace of mind, reach out to our expert team today.